- From: David Schleef <ds_at_schleef.org>
- Date: Wed, 7 Aug 2002 11:45:37 -0700
On Thu, Aug 01, 2002 at 04:35:29AM -0700, Senthil Kumar SNR wrote: > Hi > Even after using the patch it shows the same type of > error such that it seems does'nt support comedi > command. > The displayed output is : > > start : int 0 > scan_begin: timer 1000000 > convert: now 0 > scan_end: count 2 > stop: none 0 > comedi_command_test: Invalid argument > > > Should we have to make changes in the comedi_cmd > structure or else any other way....? Another stupid bug: On or around line 120, change "n_chan = 2" to "n_chan = 1". The dt282x driver doesn't allow 2-channel AO for some reason -- I don't know if there is an actual problem, or if it is an artificial limit. dave...
Received on 2002-08-07Z17:45:37