- From: David Schleef <ds_at_schleef.org>
- Date: Wed, 11 Dec 2002 12:26:39 -0800
On Wed, Dec 11, 2002 at 01:22:47PM -0600, Jason Z. Guo wrote: > I am using National Instruments pci-6071e card and > comedi-0.7.65/comedilib-0.7.19. The problem is when I use > comedi_get_range() to query the output range of subdevice 1(i.e. analog > output) with range index 2 (range should be +/- EXTREF), it always > returns [-1, 1] no matter EXTREF is disconnected or connected to 1Vol or > 1.2Vol. This is correct, since that range structure also has the RF_EXTERNAL flag set, meaning that it's in units of the external reference, not voltage. dave...