- From: Tiffany Wilkes <tdwilkes_at_ucdavis.edu>
- Date: Fri, 7 Feb 2003 10:11:10 -0800 (PST)
Hi, I have a NI 6036E multifunction I/O card. The manual lists three analog input modes: Differential, Single-ended grounded reference, and Single-ended nonreferenced. I want to select the Single-ended nonreferenced option. How do I do this with comedi? Is it related to the "aref" in comedi_data_read(comedi_t * device, unsigned int subdevice, unsigned int channel, unsigned int range, unsigned int aref, lsampl_t * data) ? What are the acceptable values for aref and what do they mean? Thanks, Tiffany