Re: comedi_command acquisition mode

On Fri, 11 Apr 2003, Fabio Cibin wrote:

> I have a problem with the comedi_command function.
> I Have seen the cmd program that is in the demo directory of comedilib, and I
> have found that if I set the cmd->stop_src = TRIG_NONE the acquisition run
> continuosly until I use comedi_cancel command.
> SO I have tried but with this option the results of the acquisition are
> absolutely errors. To verify that I have tried with a normal acquisition (not
> continuos) and all work ok.
> Is it a problem of continuos acquisition by comedi_command ?

Have you tried the comedi_command_test() function?

Herman

-- 
  K.U.Leuven, Mechanical Engineering, Robotics Research Group
<http://people.mech.kuleuven.ac.be/~bruyninc> Tel: +32 16 322480

Received on 2003-04-11Z15:29:42