Re: NI DAQCard-6062 command read/write problems

-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

On Friday 19 September 2003 12:37 pm, Michael Bird wrote:
>
> 1) When doing command analog I/O (particularly AI but I think I've seen
> it with AO
> as well)  at high sampling rates (~500 kHz),  the read/write command
> fails to return
> after writing several secons of data. In other words, the I/O operation
> works fine for
> short periods of time but then dies after several seconds.

The ai fifo size for your board was set to 1024 instead of 8192 samples in 
ni_mio_cs.c.  It should handle high speed input better now.

- -- 
Frank

-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.0.6 (GNU/Linux)
Comment: For info see http://www.gnupg.org

iD8DBQE/a1Di5vihyNWuA4URAmGzAKDmERuwBmlYLswjKiYdCVXdQEFndQCeLUQx
qmVqIwMpZMNeR7hogMpGugw=
=2lsp
-----END PGP SIGNATURE-----

Received on 2003-09-19Z17:54:26