- From: Frank Mori Hess <fmhess_at_users.sourceforge.net>
- Date: Thu, 1 Jan 2004 20:18:54 -0500
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 I've got analog output commands working with the ni 6711 now, with the cvs versions of comedi and comedilib (the ao_waveform demo in comedilib needed a little tweaking to write more samples into comedi's buffer before starting the command). Andrew, would you test the 6713? In particular, if you can look at the output on a scope, I suspect it is going to swap the order of every pair of samples in the output waveform. Also, if anyone has a 673x board in their closet, it would be nice to get the pci id numbers for them and see if they work now too. Known issues: calibration is still not supported yet - -- Frank -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.0.6 (GNU/Linux) Comment: For info see http://www.gnupg.org iD8DBQE/9McF5vihyNWuA4URAok1AJ4xScN0fy4jMNKGko3xYFTbxJj1agCeJx/3 rckhmNNB7rXuaWjh2hFfetY= =GAS5 -----END PGP SIGNATURE-----
Received on 2004-01-02Z01:18:54