- From: Christopher Greer <greer_at_oddjob.uchicago.edu>
- Date: Fri, 4 Mar 2005 14:00:48 -0600
I have used the 6033E series card. This has 64 SE inputs. I have not pushed it to its limits, but in my limited testing, the analog ins seem well behaved, now that it has been calibrated. --CG. On Mar 4, 2005, at 1:49 PM, David Schleef wrote: > On Tue, Mar 01, 2005 at 11:13:54AM -0500, Zhihong Wang wrote: >> I am trying to use comedi to collect data. >> Is there any comedi-supported card that has >> 32 analog input channels? I tried National >> Instrument website. It seems to me that >> all NI cards that have 32 ai channels are >> currently not supported. > > NI has a few E series boards that have 32 or 64 channels. These > work fine. > > I see that the rearrangement of NI's website makes the E series > boards very difficult to find. Sad, really. > > > > dave... > > > _______________________________________________ > comedi mailing list > comedi_at_comedi.org > https://cvs.comedi.org/cgi-bin/mailman/listinfo/comedi
Received on 2005-03-04Z20:00:48