Differential is measured between 0 and 8, 1 and 9, ... I've never
done this with comedi, but you should take a look at the NI manual to
see if you also need a pair of resistors to AGND to get the correct
measurements.
> Hi,
> I'm trying to do measurements where I set aref to AREF_DIFF
> with NI's board 6032E and ni_pcimio driver.
> What are channels the differential is measured? I thought they
> are pairs 0 and 8, 1 and 9 and so on but it seems that they
> are not because I get weird results. Are the pairs 0 and 1
> and so on or..? How should I set parameters to comedi_command
> to be able to measure difference between channel 0 and 8,
> 1 and 9 ... 7 and 15.
>
> Thanks and regards,
> -Santeri
>
> _______________________________________________
> comedi mailing list
> comedi_at_comedi.org
> https://cvs.comedi.org/cgi-bin/mailman/listinfo/comedi
--
Jordi Blanch Carles
Unidad de Ensayo y Control
ENCOPIM S.L.
C/. del Parc, 5 (nave 13)
P.I. Els Pinetons
E-08291 RIPOLLET (Barcelona)
Tel: (+34) 935 94 23 72
Fax: (+34) 935 94 64 15
==========================================================
La información contenida en la presente transmisión es confidencial y su
uso únicamente está permitido a su(s) destinatario(s). Si Ud. no es la
persona destinataria de la presente transmisión, rogamos nos lo
comunique de manera inmediata por teléfono (+34 935 942 347) y destruya
cualquier copia de la misma (tanto digitales como en papel).
The information contained in this transmission is confidential and is
intended only for the use of the addressee(s). If you are not the
designated recipient of this transmission, please advise us immediately
by telephone (+34 935 942 347) and destroy any copies (digital and
paper).
======================================================
Received on 2006-01-04Z08:37:27