cmd for E-Series?

If anyone on the list has modified the comedilib demo program 'cmd' to work on 
the National Instruments AT-MIO E-Series boards, I would appreciate it if you 
would email me a listing.

'cmd' works fine for me on an NI PCI-1200 & on a PCI-DAS6034, but on an NI 
AT-MIO-16DE-10 & an NI AT-MIO-16XE-50 it gives a message something like this:

command before testing:
start:      now      0
scan_begin: timer    1000000
convert:    timer    1000000
scan_end:   count    1
stop:       count    10
first test returned 0 (success)
start:      now      0
scan_begin: timer    1000000
convert:    timer    1000000
scan_end:   count    1
stop:       count    10
second test returned 0 (success)
start time: 1137681641.085558
comedi_command: Command not supported

Thanks,

sartory_at_comcast.net

Received on 2006-01-19Z15:01:02