- From: Tim van Zon <zon_at_knmi.nl>
- Date: Wed, 24 Oct 2007 06:20:26 +0000
Hi Francisco, could you try to read 6 million samples instead of 6? (should take about 48 seconds :-) ) I expect that there is a lot of overhead for initializing the card and furthermore, I think that the timing is not that accurate as well. Tim Francisco Mota wrote: > Hi folks, > > We are having the following problem with Advantec PCI 1710 AD/DA > Board: The AD convertion time interval is being much greater than > specified in the manual. We made a test with 06 (six) consecutive > readings in the AD channel and the total time spent was more than > 100us. Looking in the manual we saw that the AD conversion time is > 8us, so, we should have 48us in average. Does anybody has had this > problem before? any help will be appreciated. > Our configuration is: > Pentium IV 2800 MHz, 512 RAM, running Linux Slackware 10 - Kernel > 2.6.8.1 with RTAI 3.1, Comedi 0.7.70, Comedilib 0.7.22 > > Thanks, > Francisco Mota. > > _______________________________________________ > comedi mailing list > comedi_at_comedi.org > https://mail.comedi.org/cgi-bin/mailman/listinfo/comedi
Received on 2007-10-24Z05:20:26