Data Translation DT2815

Options
  1   Board base address
  2   IRQ (not applicable)
  3   Voltage unipolar/bipolar configuration
        0 == unipolar 5V  (0V -- +5V)
	1 == bipolar 5V  (-5V -- +5V)
  4   Current offset configuration
        0 == disabled  (0mA -- +32mAV)
        1 == enabled  (+4mA -- +20mAV)
  5   Firmware program configuration
        0 == program 1 (see manual table 5-4)
        1 == program 2 (see manual table 5-4)
        2 == program 3 (see manual table 5-4)
        3 == program 4 (see manual table 5-4)
  6   Analog output 0 range configuration
        0 == voltage
        1 == current
  7   Analog output 1 range configuration
        0 == voltage
        1 == current
  8   Analog output 2 range configuration
        0 == voltage
        1 == current
  9   Analog output 3 range configuration
        0 == voltage
        1 == current
  10  Analog output 4 range configuration
        0 == voltage
        1 == current
  11  Analog output 5 range configuration
        0 == voltage
        1 == current
  12  Analog output 6 range configuration
        0 == voltage
        1 == current
  13  Analog output 7 range configuration
        0 == voltage
        1 == current