- From: frank mori hess <fmhess_at_students.uiuc.edu>
- Date: Sun, 16 Jun 2002 12:30:11 -0500 (CDT)
On Sat, 15 Jun 2002, Daniel Koch wrote: > -----BEGIN PGP SIGNED MESSAGE----- > Hash: SHA1 > > Hi, > > We've got the following problem with our PC104das16jr/16 card. We connected a > load cell to channel 14, none of the other channels are connected and they`re > all grounded. When we start measuring, everything seems to be fine (except > from the fact that the signal we get varies pretty much..we expected it to be > steady), but when we start increasing the weight on the load cell the signal > starts scattering on channel 15 and 16 though there is nothing connected. The > more weight we put on the load cell, the more channels get involved... I > guess it`s a problem with the MUX counter on our card, but I'm not sure how > to handle this...I once read here that one fast solution would be to cut the > cables, but this is not a solution for us since we need the full length of > our cables. Did anyone encounter the same problems ? > > John, I've read your mail concerning your DAS-16 card on comedi, probably you > can help us here ? Can you send a couple lines of data so I can see exactly what you mean by 'scattering'? Frank
Received on 2002-06-16Z16:30:11