- From: Salvador Eduardo Tropea <salvador_at_inti.gov.ar>
- Date: Mon, 02 Feb 2004 13:27:25 -0300
Frank Mori Hess wrote: > >I've got a couple quibbles before I commit your code. First, I'd like to >keep the configuration instructions 'flat'. That is, just make two >seperate configuration instructions instead of making subcommands for a >single instruction. Second, your actual write to the control register >should happen during the write instruction, and INSN_CONFIG_8254_SET_MODE >should only store into memory the mode that will be used in subsequent >writes. > > > Ok, I was on vacations, I think IŽll be able to solve these issues this week. Regards, SET -- Salvador Eduardo Tropea (SET). (Electronics Engineer) Visit my home page: http://welcome.to/SetSoft or http://www.geocities.com/SiliconValley/Vista/6552/ Alternative e-mail: set_at_computer.org set_at_ieee.org Address: Curapaligue 2124, Caseros, 3 de Febrero Buenos Aires, (1678), ARGENTINA Phone: +(5411) 4759 0013
Received on 2004-02-02Z16:27:25