- From: Frank Mori Hess <fmhess_at_users.sourceforge.net>
- Date: Wed, 19 May 2004 22:16:40 -0400
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1 You can set the CR_EDGE and CR_INVERT flags in the _arg to select between edge/level and high/low triggering. Are you taking care to ground PFI1 or leaving it floating when it seems to trigger off other lines? On Wednesday 19 May 2004 05:27 am, David wrote: > Hi all > > We have configured cmd structure to adquire analog inputs with an > external trigger. > > cmd->start_src = TRIG_EXT; > cmd->start_arg = 1; > > It works but we are not sure about two things. > > First one, we can't found any place to select rising edge or falling > edge, for digital trigger. > > The second is that we have detected that other PFI trigger lines can > trigger in spite of we have selected star_arg = 1 > > Any idea about that two things? > > Thanks all > Best regards > > > -- Daniel Machón [damachon_at_eresmas.net] -- > > > _______________________________________________ > comedi mailing list > comedi_at_comedi.org > https://cvs.comedi.org/cgi-bin/mailman/listinfo/comedi - -- Frank -----BEGIN PGP SIGNATURE----- Version: GnuPG v1.2.4 (GNU/Linux) iD8DBQFArBUI5vihyNWuA4URAsFeAKDfOLrsSlMckBidoTObqLWyEefkZgCcCk2z MEjIF4Lu39FZS+I+afYzyDc= =YstF -----END PGP SIGNATURE-----
Received on 2004-05-20Z01:16:40