- From: Steven Hartmann <shartmann_at_militho.com>
- Date: Wed, 05 Jul 2006 19:20:42 -0500
M series support is not complete. I think the 625x cards seem to work better than the 622x cards. You didn't say which you had. sphericaline_at_aim.com wrote: > We are trying to use an external trigger to start a scan on an M Series > NiDaq card. > > The comedi_get_subdevice_flags function produces "ni_mio_common: ai > error a_status = 88b0" and when the read function is reached shortly > after, we get a "Broken pipe" error. > > We are using 100 kHz square wave into PFI 2. The scan_begin_src flag > is set to TRIG_EXT and scan_begin_arg is set to 2. > > Any suggestions or advice would be most appreciated. > > Daryl Ng > ________________________________________________________________________ > Check Out the new free AIM(R) Mail -- 2 GB of storage and > industry-leading spam and email virus protection. > > > _______________________________________________ > comedi mailing list > comedi_at_comedi.org > https://cvs.comedi.org/cgi-bin/mailman/listinfo/comedi >
Received on 2006-07-05Z23:20:42