- From: Ian Abbott <abbotti_at_mev.co.uk>
- Date: Wed, 13 Jun 2007 10:14:24 +0100
On 06/06/2007 21:05, Paulo André Capellari wrote: > Hello for all! > > I'm new here and want a newby information ;) > > I've seen the use of INT_TRIG to start an "aquisition", but I'm looking > for something like this to start a "scan"... someone can help-me? > > thanks! I don't think any of the drivers support using a software trigger to start a "scan", but most (?) of them support starting an "acquisition" that way. You could configure the acquisition to stop after one scan (stop_src = TRIG_COUNT, stop_arg = 1) and set up the acquisition again each time it completes. -- -=( Ian Abbott _at_ MEV Ltd. E-mail: <abbotti_at_mev.co.uk> )=- -=( Tel: +44 (0)161 477 1898 FAX: +44 (0)161 718 3587 )=-
Received on 2007-06-13Z08:14:24